The DS1318E+ is a parallel-interface elapsed time counter in 24 pin TSSOP package. This ETC is a 44bit counter that maintains the amount of time that the device operates from main and/or backup power or during an external event. The internal frequency of the counter clock is 4.096KHz which provides a 244µs resolution and a maximum count of over 136 years. A built-in power-sense circuit detects power failures, automatically switches to the backup supply and controls the timer. If an external event timer is desired, the control input EXT can control the counter operation. An open-drain output provides an interrupt and a square-wave output provides a programmable square wave. It is accessed through a byte wide parallel interface. Device is used in power meters and servers.
Supply voltage range is 3V to 3.6V
Operating temperature range from -40°C to 85°C
Internal power-fail circuit allows timer to provide primary or battery operation times
Timer can alternately provide an event timer of either an active-high or active-low pulse
Interrupt output generated periodically or when upper 32bits of the counter match an alarm register
Square-wave output with 16 selectable frequencies from 32.768KHz to 0.5Hz