sales@aipcba.com
CN
电子元器件采购 > TI >

TPIC46L02 库存 & 价格

TPIC46L02
显示的图像仅供参考,应从产品数据表中获得准确的规格。
TPIC46L02 TI
TI
  • 制造商:
    TI
  • 制造商型号#:
    TPIC46L02
  • 百芯编号#:
    CM392911622
  • 价格(CNY):
  • 百芯库存:
    243
  • 可供应量:
    170 个在库
    此为供应商库存,需要与销售确认
  • 产品描述:
    6Channel Serial/Parallel Low-Side Pre-FET Driver
  • 文档: 符合 RoHS 标准 3D模型
TPIC46L02 购买 TPIC46L02 库存和价格更新于 2024-05-17 03:50:22
  • 刷新
    器件型号: TPIC46L02
    百芯编号: CM392911622
    制造商: TI
    价格
    总计: 413
    MOQ: 1
    库存地点: 香港
    发货日期: 2024/05/22 (预期 )
  • 购买
    *由于库存数量、价格不断波动,请 联系我们 获取型号最新价格和库存。

    元器件库存查询

    库存查询
    百芯库存涵盖200,000个元器件
    欺诈预防提醒
    近日,我们发现不法分子冒充百芯智造进行诈骗或试图低价销售假冒和故障元器件。
    百芯智造在2021年建立了一个 元器件检测实验室 ,旨在提供有质量保证的组件。
    我们强烈建议客户选择可靠的元器件供应商。
    请注意,唯一电子邮件后缀是 aipcba.com
    类型
    描述
    选择
    制造商
    TI
    安装方式
    Surface Mount
    3D模型
     3D模型
    封装
    SSOP-28
    显示相似产品
    TPIC46L02 数据规格书
    TPIC46L02 数据手册Datasheet
    20 Pages, 267 KB
    2006/01/09
    查看
    符合标准
    类型
    描述
    RoHS标准
    RoHS Compliant
    含铅标准
    Lead Free
    产品概述
    • The TPIC46L01, TPIC46L02, and TPIC46L03 are low-side predrivers that provide serial input interface and parallel input interface to control six external field-effect transistor(FET) power switches such as offered in the Texas Instruments TPIC family of power arrays. These devices are designed primarily for low-frequency switching, inductive load applications such as solenoids and relays. Fault status for each channel is available in a serial-data format. Each driver channel has independent off-state open-load detection and on-state shorted-load/short-to-battery detection. Battery overvoltage and undervoltage detection and shutdown are provided. Battery and output load faults provide real-time fault reporting to the controller. Each channel also provides inductive-voltage-transient protection for the external FET.
    • These devices provide control of output channels through a serial input interface or a parallel input interface. A command to enable the output from either interface enables the respective channel GATE output to the external FET. The serial input interface is recommended when the number of signals between the control device and the predriver must be minimized, and the speed of operation is not critical. In applications where the predriver must respond very quickly or asynchronously, the parallel input interface is recommended.
    • For serial operation, the control device must transition CS\ from high to low to activate the serial input interface. When this occurs, SDO is enabled, fault data is latched into the serial input interface, and the FLT\ flag is refreshed.
    • Data is clocked into the serial registers on low-to-high transitions of SCLK through SDI. Each string of data must consist of 8 bits of data. In applications where multiple devices are cascaded together, the string of data must consist of 8 bits for each device. A high data bit turns the respective output channel on and a low data bit turns it off. Fault data for the device is clocked out of SDO as serial input data is clocked into the device. Fault data consists of fault flags for the over-battery voltage (bit 8), under-battery voltage (bit 7) (not on TPIC46L03), and shorted/open-load flags (bits 1-6) for each of the six output channels. A logic-high bit in the fault data indicates a fault and a logic-low bit indicates that no fault is present on that channel. Fault register bits are set or cleared asynchronously to reflect the current state of the hardware. The fault must be present when CS\ is transitioned from high to low to be captured and reported in the serial fault data. New faults cannot be captured in the serial register when CS\ is low. CS\ must be transitioned high after all of the serial data has been clocked into the device. A low-to-high transition of CS\ transfers the last 6 bits of serial data to the output buffer, puts SDO in a high-impedance state, and clears and reenables the fault register. The TPIC46L01/L02/L03 was designed to allow the serial input interfaces of multiple devices to be cascaded together to simplify the serial interface to the controller. Serial input data flows through the device and is transferred out SDO following the fault data in cascaded configurations.
    • For parallel operation, data is asynchronously transferred directly from the parallel input interface (IN0-IN5) to the respective GATE output. SCLK or CS\ are not required for parallel control. A 1 on the parallel input turns the respective channel on, where a 0 turns it off. Note that either the serial interface or the parallel interface can enable a channel. Under parallel operation, fault data must still be collected through the serial data interface.
    • The predrivers monitor the drain voltage for each channel to detect shorted-load or open-load fault conditions in the on and off states respectively. These devices offer the option of using an internally generated fault-reference voltage or an externally supplied VCOMP for fault detection. The internal fault reference is selected by connecting VCOMPEN to GND and the external reference is selected by connecting VCOMPEN to VCC. The drain voltage is compared to the fault-reference voltage when the channel is turned on to detect shorted-load conditions and when the channel is off to detect open-load conditions. When a shorted-load fault occurs using the TPIC46L01 or TPIC46L03, the channel is turned off and a fault signal is sent to FLT\ as well as to the serial fault-register bit. When a shorted-load fault occurs while using the TPIC46L02, the channel transitions into a low-duty cycle, pulse-width-modulated (PWM) signal as long as the fault is present. Shorted-load conditions must be present for at least the shorted-load deglitch time, t(STBDG), in order to be flagged as a fault. A fault signal is sent to FLT\ as well as the serial fault register bit. More detail on fault detection operation is presented in the device operation section of this data sheet.
    • The TPIC46L01 and TPIC46L02 provide protection from over-battery voltage and under-battery voltage conditions irrespective of the state of the output channels. The TPIC46L03 provides protection from over-battery voltage conditions irrespective of the state of the output channels When the battery voltage is greater than the overvoltage threshold or less than the undervoltage threshold (except for the TPIC46L03, which has no undervoltage threshold), all channels are disabled and a fault signal is sent to FLT\ as well as to the respective fault register bits. The outputs return to normal operation once the battery voltage fault has been corrected. When an over-battery/under-battery voltage condition occurs, the device reports the battery fault, but disables fault reporting for open and shorted-load conditions. Fault reporting for open and shorted-load conditions are reenabled after the battery fault condition has been corrected.
    • These devices provide inductive transient protection on all channels. The drain voltage is clamped to protect the FET. This clamp voltage is defined by the sum of VCC and turn-on voltage of the external FET. The predriver also provides a gate-to-source voltage (VGS) clamp to protect the GATE-source terminals of the power FET from exceeding their rated voltages.
    • These devices provide pulldown resistors on all inputs except CS\\. A pullup resistor is used on CS\\.
    • 6-Channel Serial-In/Parallel-In Low-side Pre-FET Driver
    • Device Can Be Cascaded
    • Internal 55-V Inductive Load Clamp and VGS Protection Clamp for External Power FETs
    • Independent Shorted-Load/Short-to-Battery Fault Detection on All Drain Terminals
    • Independent Off-State Open-Load Fault Sense
    • Over-Battery-Voltage Lockout Protection and Fault Reporting
    • Under-Battery Voltage Lockout Protection for TPIC46L01 and TPIC46L02
    • Asynchronous Open-Drain Fault Flag
    • Device Output Can Be Wire-ORed With Multiple External Devices
    • Fault Status Returned Through Serial Output Terminal
    • Internal Global Power-On Reset of Device
    • High-Impedance CMOS Compatible Inputs With Hysteresis
    • TPIC46L01 and TPIC46L03 Disables the Gate Output When a Shorted-Load Fault Occurs
    • TPIC46L02 Transitions the Gate Output to a Low-Duty Cycle PWM Mode When a Shorted-Load Fault Occurs

    百芯智造认证

    百芯智造承诺产品质量和安全通过ISO 9001、ISO 13485、ISO 45001、UL、RoHS、CQC 和 REACH 认证
    查看我们的认证 >
    订购详情及相关信息
    •  此处条款仅供参考,实际条款以销售报价为准。
      - 订购时请确认产品规格。
      - MOQ 是指购买每个零件所需的最小起订量。
      - 如果您有特殊的订购说明,请在订购页面注明。
      - 装运前会进行检验 (PSI)。
      - 您可以随时给我们发邮件查询订单状态。
      - 包裹发货后无法取消订单。
    • - 提前电汇(银行转账),也可选择PayPal。
      - 仅限现金转账。(不接受支票和账单转账。)
      - 客户负责支付所有可能的费用,包括销售税、增值税和海关费用等。
      - 如果您需要详细的发票或税号,请给我们发送电子邮件。
    • - 可选择顺丰或跑腿。
      - 您可以选择是通过您的运费帐户收取运费还是由我们收取。
      - 偏远地区请提前与物流公司确认。
      (在这些地区送货可能会收取额外费用(35-50 美元)。)
      - 交货日期:通常为 2 到 7 个工作日。
      - 您的订单发货后将发送跟踪号。
    • - 由百芯智造仓库仔细检查和包装
      - 真空包装
      - 防静电包装
      - 防震泡沫
    • - 收入质量控制 (IQC),800多家合格经销商。
      - 500m² 高级元器件检测实验室、假冒检测、RoHS 合规性等
      - 2000㎡数码元器件仓库,恒温恒湿
      - 开盖检查
      - X-Ray检查
      - XRF检查
      - 电气测试
      - 外观检测
    • - 不合格和假冒检测
      - 故障分析
      - 电气测试
      - 生命周期和可靠性测试
      -百芯2021年成立元器件检测实验室
      了解更多 >

    电子元件供应服务

    立即查看
    SN:H0.46555LO5622V47Q0QC0S1
    在线联系我们
    黄经理 - 百芯智造销售经理在线,5 分钟前
    您的邮箱 *
    消息 *
    发送