Incorporate Honeywell"s MLH010BGD14E industrial pressure sensor into your system to quickly generate pressure related data. It has a voltage of 0.5 to 4.5 V. This device"s minimum operating supply voltage of 7 V, while its maximum is 30 V. This part has a minimum operating temperature of -40 °C and a maximum of 125 °C. It has a response time of 2 ms. Its operating pressure range is 0bar to 10bar, while its maximum overload pressure is 100bar.