APPLICATION NOTE 6410
SIGNAL-TO-NOISE RATIO AS A
QUANTITATIVE MEASURE FOR OPTICAL
BIOSENSORS
Abstract: This application note provides an overview of the importance of SNR in evaluating Maxim
Integrated advanced sensor products. It also goes into the details of SNR testing, including setup
and procedure, as well as the interdependency of SNR and power consumption. Finally, it
discusses new ways of evaluating SNR for human PPG signal.
Introduction
When evaluating a Maxim Integrated sensor product, it is extremely important to characterize signal
to noise ratio (SNR). In biosensors, such as Maxim’s sensors, lower noise in the signal facilitates
faster time to report results. Therefore, a device with higher SNR enhances user experience by
shortening time to report human vitals while increasing accuracy of results at the same time.
Like most other electronic devices in the market, Maxim parts can be evaluated by measuring noise
under various conditions or configurations and comparing it to the desired signal under the same
conditions. That comparison, achieved through SNR, provides the evaluator with a leading indicator
of measurement accuracy in the various operating environments and conditions.
SNR: An Effective Approach to Performance Evaluation
Defined as the ratio of signal power and noise power, SNR considers noise from all sources such
as electrical, thermal, optical, and even environmental noise.
If the impedance for signal and noise is the same, SNR can be calculated using the amplitude of
signal and the amplitude of the noise. Therefore, SNR can be expressed as:
When expressing SNR in dB, it would then be calculated as:
Page 1 of 8

MAX30101ACCEVKIT# 数据手册 PDF

MAX30101ACCEVKIT# 数据手册
Maxim Integrated
14 页, 3071 KB
MAX30101ACCEVKIT# 其它数据手册
Maxim Integrated
1 页, 262 KB
MAX30101ACCEVKIT# 应用笔记
Maxim Integrated
8 页, 658 KB

MAX30101 数据手册 PDF

MAX30101
数据手册
Maxim Integrated
High-Sensitivity Pulse Oximeter and Heart-Rate Sensor for Wearable Health
MAX30101EFD+
数据手册
Maxim Integrated
Biomedical Sensors Integrated Optical Sensor
MAX30101EFD+T
数据手册
Maxim Integrated
Biomedical Sensors Integrated Optical Sensor
MAX30101ACCEVKIT#
数据手册
Maxim Integrated
MAXIM INTEGRATED PRODUCTS MAX30101ACCEVKIT# Evaluation Module, Sensor, Pulse Oximeter & Heart Rate Monitor
Datasheet 搜索
搜索
百芯智造数据库涵盖1亿多个数据手册,每天更新超过5,000个PDF文件。
在线联系我们
黄经理 - 百芯智造销售经理在线,5 分钟前
您的邮箱 *
消息 *
发送